EN
CN

PRODUCTS NAME

IR-5
Test item
Human visual parallax E2000 chromatic aberration ΔE ΔH ΔC LAB coordinate CIE XY difference Int

detectability

Detection capability

Detection speed

Detection accuracy

Repeatability accuracy

GLOBAL PARTNER

DEMO VIDEO

View video
This video will show you how to operate the product in detail, not to miss every detail. Let you easily grasp all the points during the viewing process.
Product introduction


When we measure the reflectance of anti-reflection film on the lens,  Traditional scheme can reduce the reflection of the substrate and the other side surface of the lens by frosting one side of lens to the black color. The process is tedious and will create operating errors.

IR-5 adopts a unique confocal scheme with a very short focal depth to support direct measurement of surface of the sample, free from reflected light from other objects to achieve non-contact and non-destructive testing.


Advanced general color difference △ E2000

CIE is more advanced in calculation of color aberration by the difference of the human eye sensitivity to color. More accurate simulation of subjective chromatic aberration of human eye can be obtained. As can be seen from the photo below, the human eye is most sensitive to orange color while least sensitive to cyan color .

* * * Note: The shorter the minor axis of the elliptical shape in the figure, the smaller the color tolerance.



镜片膜层反射率测量仪











The change in reflected color of samples under different ambient light


Samples show different colors under different ambient light, and iR-5 provides standard irradiation at different color temperature and calculates the chromaticity values at 2 ° and 10 ° from observer’s angle respectively. The objective and accurate measurement results can be used to guide the reproduction of color coating and anti-reflection coating technology, and provide color reports between standard sample and tested sample, or anti-reflection Film Report as per ISO Standard. 


Optical fiber confocal mode to avoid interference of light


When measuring the reflectivity of the anti-reflection film of the lens, the traditional scheme can reduce the reflection of the substrate and the other side surface of the lens by frosting one side of lens to the black color. The process is tedious and will create operating errors. iR-5 adopts a unique confocal scheme with a very short focal depth to support direct measurement of surface of the sample, free from reflected light from other objects to achieve non-contact and non-destructive testing.


Comparison of tested sample and master sample 

In below photo, white cross is standard sample while black cross is master sample

image.pngimage.png
**   CIE1931 Color Coordinate                                                     CIE1976 Color Coordinate 


”S” in orange is master sample, ”T” in blue is tested sample

image.png


Reflectance curve for tested sample and master sample

image.png


Function:


Reflectance curve chart: Display reflectance curve (range :380 ~ 850 nm) . The wavelength can be customized within range

Chart Graduation Line: Display vertical and horizontal graduation lines

Quick Preview on Reflectance :The vertical graduation line can display corresponding reflectance of current wavelength

Reflection color contrast:The color difference can be calculated by comparing real-time data with those from master sample

Sampling interval: Calculation of pv, pm at 1nm or 5nm wavelength interval

Sample Information: Input of sample testing company and sample information

Reflection colorimetric report: Reflection colorimetric report output showing chromatic aberration, color coordinate

Reflection report: report and reflectance curve as per ISO and GB testing standard

Data save:Support file archived in TXT and Excel

Color calculation: Human visual parallax E2000, chromatic aberration ΔE, ΔH, ΔC and LAB coordinate ,CIE XY difference

ISO standard light source calculation: A D65 C D50a D55 D75 ID65 ID50 light source calculation

ISO observer's angle: 2 ° and 10 ° calculations

Reflectance display: Integral reflectance pv, average reflectance pm,  reflectance at single wavelength pλ

Computer configuration:Windows 10/11





Software demonstration
  • Product introduction
  • Software interface
Send your lens , and we will do the test for you
Sample test
Recommended product
Leave a message now to get product information

(First step)

Sample testing process

01Learn about your sample information
Fill in the sample test request form and submit it
02Send your sample
After submitting the form, you will receive detailed shipping instructions
03Detection completed
You will receive a detailed sample test report
Email address*

(The second step)

Please fill in below information before sending us lens sample

  • Sample type

  • Company name*

  • Full name

  • Phone number*

  • Which testing items or index are important for you?

  • Which device do you want to test the sample with?

  • Code*

We have got your details and will contact you very soon
Thank you so much!

Back home